国产成人综合视频一区_日韩人妻AV无码区_黄页网站在线观看_拍拍拍无遮无挡视频1000_日本真人添下面视频免费_亚洲中文字幕永久无线码_成a人片在线观看www流畅_特别污特别黄网站_亚洲欧美日韩图片_日韩乱码一区中文字幕

Shenzhen Guodian Xuzhen Electric Technology Co., Ltd.

Product

product demand

We can customize according to your needs, please fill in the form below.

Why Customize?

You only need to fill in your needs, purposes, we will provide personalized customization.

contact us

You can also contact us in the following ways

support hotline:
TEL:400-698-3738
Shenzhen Guodian Xuzhen Electric Technology Co., Ltd. Address:
龍崗區(qū)龍城街道五聯(lián)瓦窯東路26號安能泰工業(yè)園
Intelligent phase sequence tester
產(chǎn)品型號: GD010

During the commissioning process of the hydropower generating set, it is necessary to check whether the phase sequence of power generation and grid power is correct. If it is not difficult after the generator voltage is successfully built, the ordinary phase sequence table can do it. However, some g...

sales network
Please select the address closest to you, and we will find the nearest dealer for you to serve you!
Province
Features
Phase sequence determination:
Connect the DC5V power supply to the tester, and connect the detected three-phase voltage to the "excitation On the U, V, W terminals of "Magnetic Output Voltage", if the voltage is between AC20-450V, the display screen will directly display "Positive Phase Sequence" or "reverse phase sequence"; if the voltage is not enough, press the "stop" button once, then press the start button (or use the battery to charge the excitation coil< /span>Power off), let go after the voltage rises above AC50V. The display will directly display "positive phase sequence" or "reverse phase sequence";

Excitation control phase sequence phase determination:
Connect the DC5V power supply to the tester, and connect the three-phase voltage output by the excitation transformer to the tester On the U, V and W terminals of the "excitation variable output voltage" of the tester, connect the generator's motorterminal voltage A and C to the tester's "motor". terminal voltage” on the U and W terminals. If the voltage of each phase is between AC20-450V, the display will directly showExcitation transformer output is "positive phase sequence" or "reverse phase sequence". At the same time, "Phase Offset Angle"indicates the angle at which "Excitation Transformer Output AC Phase Voltage" lags behind "Machine Terminal AC Voltage"degrees. If the voltage of each phase is lower than AC20V at this time, press the "stop" button, then Then press the start button (or charge the excitation coil with a battery), and let go after the voltage rises to AC50V or more. The display will show whether the excitation transformer output is "positive phase sequence" or "reverse phase sequence". At the same time, "Phase Offset Angle" indicates the angle by which "Excitation TransformerOutput AC Phase Voltage" lags behind "Machine Terminal AC Voltage". If the excitation transformer is Yd11 type, the "phase offset angle" should be about 330 degrees, otherwise it may be a wiring error. If the excitation transformer is YY type, "Phase Offset Angle" should be about 0 degrees or 360 degrees, otherwise it may be a wiring error. If you use our company's brushed excitation controller, no matter whether the wiring is wrong, you can Directly set the detected "phase offset angle" into the 20th item "Phase Offset" of the excitation controller settings, then the encourage operation.
technical parameter
◆Input voltage: AC0-200V, long-term, AC200-450V, 60S;
◆ Power supply DC5V, 300mA (normal mobile phone charging power supply or power bank);
◆Appearance: 188(width)*128(height)*51(thickness)mm, 350g
Case show
  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station

  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station

  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station