Overcurrent and overvoltage protector
產(chǎn)品型號: GDB-1

It is suitable for the protection of high and low voltage generators and switch cabinets. It is suitable for the integration of host control equipment manufacturers and automation enterprises to form a device for safe operation of the power system. With overvoltage, low pressure, overcurrent (overlo...

sales network
Please select the address closest to you, and we will find the nearest dealer for you to serve you!
Province
Features
◆ With high-end microcontroller as the core, high precision, stability and reliability;
◆ Centralized control, simple wiring and easy installation;
◆ Replaces the traditional multiple relay protection mode;
◆ With over-voltage, low-voltage, over-current (overload) protection functions;
◆ Inverse time control for overcurrent protection;
◆ The parameters can be modified in real time for special generators; all parameters are password protected;
◆ Fault indicator, buzzer alarm, four-digit digital display three-dimensional fault judgment.
technical parameter
◆Input Signal:
(1) PT voltage:
     a. Nominal 100V generator PT (voltage transformer) voltage
     b. Nominal 230V generator phase voltage
     c. Nominal 400V generator line voltage
(2) Three-phase current:          
     Nominal 5A generator three-phase CT (current transformer) current signal
    (note that the end of the same name is on the same side, CT linear range: 0-7A
◆Output signal:     
    Relay on and off signal (with two ways of normally open and normally closed)
    Relay contact capacity: AC 220V/5A 380V/2A
    DC 110V/0.8A 220V/0.2A
◆Voltage measurement accuracy: no less than ±1%
◆Current measurement accuracy: no less than ±1%
◆Working power supply: AC 150V~360V DC 220V
◆Power consumption: less than 6W
◆Working environment   Ambient temperature: -5℃~+45℃
  Relative humidity: not more than 90% (40℃) below 2500 meters above sea level

◆Installation size: (L) 114×(W) 114 (D) 108mm (see installation diagram)
Case show
  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station

  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station

  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station