◆In addition to meeting the requirements of general electronic components for the surrounding environment in the application of low-voltage electronic control equipment, input signalrequiredAs follows:
VIN: (Ve+2V)≤VIN≤20V,Rated output≤10V, 12V is recommended.
How to use
GDD-1CNormaltype digital potentiometer itself is a small plastic 50×85×20mm Square box, there is an indicator light and two built-in increase and decrease buttons under the cover. There is a row of wiring sockets on the left side of the cover, which must be connected correctly according to the wiring diagram; there is a pair of φ3 mounting holes on the opposite corners, which can have M3 screws or Self-tapping screws are installed on the base plate near the control object. There is a set of selector switches in the lower right corner to select different power-on reset voltages .
Atype, Btype setting method is as follows:
◆The position of NO1, NO2, NO3 and NO4 is OFF and select 0 %.
◆Select 4(10)% for the position of NO1 ON.
◆The position of NO1 is OFF, and the position of NO2 is ON, select 8(20)%.
◆NO1, select 12(30) % for NO2 position OFF and NO3 position ON.
◆NO1, NO2, NO3 position OFF, NO4 position ON select 16(40) %.
C, DThe type is as follows:
◆ The positions of NO1, NO2, NO3, and NO4 are OFF as 0 and ON as 1 to form a 4-bit binary code 0~15, and NO4 is the high bit.