国产成人综合视频一区_日韩人妻AV无码区_黄页网站在线观看_拍拍拍无遮无挡视频1000_日本真人添下面视频免费_亚洲中文字幕永久无线码_成a人片在线观看www流畅_特别污特别黄网站_亚洲欧美日韩图片_日韩乱码一区中文字幕

Shenzhen Guodian Xuzhen Electric Technology Co., Ltd.

Product

product demand

We can customize according to your needs, please fill in the form below.

Why Customize?

You only need to fill in your needs, purposes, we will provide personalized customization.

contact us

You can also contact us in the following ways

support hotline:
TEL:400-698-3738
Shenzhen Guodian Xuzhen Electric Technology Co., Ltd. Address:
龍崗區(qū)龍城街道五聯(lián)瓦窯東路26號(hào)安能泰工業(yè)園
Smart Potentiometer
產(chǎn)品型號(hào): GDD-1

Controlled rectifiers are widely used in power system excitation and industrial control devices. At present, most of the controllable rectifier devices used in China adopt analog control, the given is generally a voltage signal, and the given method uses a potentiometer or a non-contact ma...

sales network
Please select the address closest to you, and we will find the nearest dealer for you to serve you!
Province
Features

◆GDD-1C digital potentiometer adopts eight-bit single-chip microcomputer as the core, with simple hardware, high reliability, high precision and perfect performance. The control and stabilization accuracy are both within 0.2%, and the actual observed stabilization accuracy is within 0.1% around. It has two start-up reset functions. One is power-on reset, it automatically gives the selected voltage; the other is external reset, after the system trips, in order to prevent the rapid rise of voltage willThe tripping signal (can use the normally closed contact of the closing switch (preferably via a small intermediate relay)) is introduced as an external reset signal, after resetvoltage Return to the voltage level selected on power-up. ResetVoltageCan be selected with the small toggle switch in the box, with maximum outputVoltageVe0%, 4%, 8%, 12%, 16% (Atype) and 0%, 10%, 20%, 30%, 40% (Type B) and 0%, 4%, 8%, 12%, 16%, 20%, 24%, 28%, 32%, 36%, 40%, 44%, 48%, 52 %, 56%, 60% (Ctype) and 0%, 44 %, 48%, 52%, 56%, 60%, 64%, 68%, 72%, 76%, 80%, 84%, 88%, 92%, 96%, 100% (D< span style="font-size:18px;">type) four options are available to suit different needs.

GDD-1C digital potentiometer is a common type, and the light/dark time ratio of a single-color LED is used to roughly display the voltage output size. A, B, C type rise and fall time is about 45 seconds; D type is about 7.5seconds, and the rise time is about 4 seconds.

technical parameter

◆In addition to meeting the requirements of general electronic components for the surrounding environment in the application of low-voltage electronic control equipment, input signalrequiredAs follows:

VIN: (Ve+2V)≤VIN≤20V,Rated output≤10V, 12V is recommended.


How to use

GDD-1CNormaltype digital potentiometer itself is a small plastic 50×85×20mm Square box, there is an indicator light and two built-in increase and decrease buttons under the cover. There is a row of wiring sockets on the left side of the cover, which must be connected correctly according to the wiring diagram; there is a pair of φ3 mounting holes on the opposite corners, which can have M3 screws or Self-tapping screws are installed on the base plate near the control object. There is a set of selector switches in the lower right corner to select different power-on reset voltages .

Atype, Btype setting method is as follows:

◆The position of NO1, NO2, NO3 and NO4 is OFF and select 0 %.

◆Select 4(10)% for the position of NO1 ON.

◆The position of NO1 is OFF, and the position of NO2 is ON, select 8(20)%.

NO1, select 12(30) % for NO2 position OFF and NO3 position ON.

◆NO1, NO2, NO3 position OFF, NO4 position ON select 16(40) %.

C, DThe type is as follows:

◆ The positions of NO1, NO2, NO3, and NO4 are OFF as 0 and ON as 1 to form a 4-bit binary code 0~15, and NO4 is the high bit.

binary 0~15 correspond to C type respectively: 0%, 4%, 8%, 12%, 16%, 20%, 24%, 28%, 32%, 36%, 40%, 44%, 48%, 52%, 56%, 60%; DType:0%, 58%, 61 %, 64%, 67%, 70%, 73%, 76%, 79%, 82%, 85%, 88%, 91%, 94%, 97%, 100%.

Case show
  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station

  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station

  • Automatic power generation control system for hydropower station
    enlarge

    Automatic power generation control system for hydropower station